This archive is retained to ensure existing URLs remain functional. It will not contain any emails sent to this mailing list after July 1, 2024. For all messages, including those sent before and after this date, please visit the new location of the archive at https://mailman.ripe.net/archives/list/[email protected]/
[atlas] CLI
- Previous message (by thread): [atlas] Probe name rules
- Next message (by thread): [atlas] CLI
Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
Milad Afshari
afshar.milad89 at gmail.com
Sun Jun 3 14:23:36 CEST 2018
Hi Stephane, Thanks for your suggestion, I have installed the " blaeu" and It is working better now. On Wed, May 30, 2018 at 11:22 AM, Stephane Bortzmeyer <bortzmeyer at nic.fr> wrote: > On Wed, May 30, 2018 at 11:13:11AM +0430, > Milad Afshari <afshar.milad89 at gmail.com> wrote > a message of 97 lines which said: > > > Exception in thread Thread-1 (most likely raised during interpreter > shutdown): > > Traceback (most recent call last): > > File "/usr/lib/python2.7/threading.py", line 801, in __bootstrap_inner > > File "/usr/lib/python2.7/dist-packages/socketIO_client/heartbeats.py", > line 27, in run > > File "/usr/lib/python2.7/dist-packages/socketIO_client/__init__.py", > line 192, in _ping > > File "/usr/lib/python2.7/dist-packages/socketIO_client/transports.py", > line 159, in send_packet > > <type 'exceptions.TypeError'>: 'NoneType' object is not callable > > Unhandled exception in thread started by > > sys.excepthook is missing > > lost sys.stderr > > It seems a bug in the tool, to me, may be triggered by some MiTM TLS > interceptor. In the case it is specific to the streaming interface, > you may try a tool which does not use this interface (weaknesses can > be strengths :-) > <https://labs.ripe.net/Members/stephane_bortzmeyer/ > creating-ripe-atlas-one-off-measurements-with-blaeu>: > > % blaeu-reach --probes 33717 9.9.9.9 > 1 probes reported > Test #13596250 done at 2018-05-30T06:46:37Z > Tests: 3 successful tests (100.0 %), 0 errors (0.0 %), 0 timeouts (0.0 %), > average RTT: 130 ms > > Or with your measurement (which indeed worked): > > % blaeu-reach --measurement-ID 13595420 --probes 33717 9.9.9.9 > Warning: --probes ignored since we use probes from a previous measurement > Test #13595420 done at 2018-05-30T06:29:04Z > Tests: 3 successful tests (100.0 %), 0 errors (0.0 %), 0 timeouts (0.0 %), > average RTT: 130 ms > > If you have time to test, tell me if it works better. > -------------- next part -------------- An HTML attachment was scrubbed... URL: </ripe/mail/archives/ripe-atlas/attachments/20180603/4be9741e/attachment.html>
- Previous message (by thread): [atlas] Probe name rules
- Next message (by thread): [atlas] CLI
Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]